Are tubes containing sodium fluoride still needed for the measurement of blood glucose in hospital laboratory practice?.

Identifier
DOI 10.5001/omj.2014.109
Publisher
Oman Medical Specialty Board.
Gregorian
2014-11
Language
English
English abstract
Objectives: To compare glucose values obtained using sodium flouride (NaF) tubes and serum separation tubes (SST) in a tertiary care hospital laboratory setting. Methods: This study was conducted at the Clinical Biochemistry Laboratory, Royal Hospital, Oman. During the study period (1 September–30 November 2013), 50 pairs (one NaF tube and one SST) of patient's blood specimens were randomly collected. Following separation of plasma (NaF tubes) and serum (SST), glucose concentrations were measured by hexokinase assay using the Architect c8000. Fifteen pairs of these tubes were kept in the refrigerator at 4°C and plasma/serum glucose concentrations were measured daily up to seven days after collection. Results: Comparing plasma (NaF) and serum (SST) results of glucose values (n=50) showed an average difference of 0.00mmol/L (range -0.60 to +0.60mmol/L). Bland Altman analysis gave a non-significant constant bias of 0.10 ±0.195mmol/L (bias ±SD). Pearson correlation between plasma (NaF) and serum (SST) glucose concentrations revealed a significant correlation approaching unity with r2= 0.9991. No significant differences in glucose values were noted for both plasma and serum in 15 pairs of NaF and SST tubes when analyzed seven days following refrigeration. Hemolysis was observed in five (10%) NaF tubes compared with two (4%) SST. Conclusion: There is no difference in glucose values collected from plasma NaF tubes or serum SST, and so SST can be used in hospital laboratory settings as there are practical advantages, including cost-effectiveness and reduction in blood volume drawn when utilizing these tubes for glucose and other tests from a single blood collection tube.
Member of
Citation
Al-Kharusiyah, Amira, Al-Lawatiyah, Nuha, Al-Kindiyah, Manal, & Mula-Abed, Waad-Allah S. (2014). Are tubes containing sodium fluoride still needed for the measurement of blood glucose in hospital laboratory practice?. Oman Medical Journal, 29 (6), 404-407
Category
Journal articles

Same Subject

Journals and Periodicals
5
0
Al-Maskar, Awatif Y.
SQU MED
2011-05
Theses and Dissertations
0
0
Al-Khaliliyah, Shafiya Ahmed Hilal.
Sultan Qaboos University
2007
Theses and Dissertations
0
0
Al -Sinaniyah, Sawsan Salim Sultan.
Sultan Qaboos University
2014
Theses and Dissertations
0
0
Al-Aamriyah, Laila Humaid Salim.
Sultan Qaboos University
2014
Theses and Dissertations
0
0
Al-Saleh, Mohsen Mohammed Taqi Mohsen
Sultan Qaboos University
2013